nomadpainting.blogg.se

Emc powerpath download windows 2012 r2
Emc powerpath download windows 2012 r2










emc powerpath download windows 2012 r2
  1. EMC POWERPATH DOWNLOAD WINDOWS 2012 R2 INSTALL
  2. EMC POWERPATH DOWNLOAD WINDOWS 2012 R2 DRIVERS
  3. EMC POWERPATH DOWNLOAD WINDOWS 2012 R2 SOFTWARE
  4. EMC POWERPATH DOWNLOAD WINDOWS 2012 R2 PASSWORD

On the confirmation page, you can select to automatically reboot the server, but this feature does not require a reboot. Once you have located it, click the box beside it and ensure a check mark appears, then click “Next”. You may need to scroll down to see the “Multipath I/O” option.

emc powerpath download windows 2012 r2

EMC POWERPATH DOWNLOAD WINDOWS 2012 R2 INSTALL

To install this feature from the dashboard, click on the “Add Roles and Features” selection.Ĭlick the “Next” radio button until you reach the “Feature” selection page. The first step is the installation of the MPIO feature.

emc powerpath download windows 2012 r2

Otherwise, the instructions below will walk you through configuring the MPIO feature in Windows Server 2012 for multipath failover in a SAN environment. However, if you still chose to use PowerPath, the minimal version needed will be PowerPath 5.7 SP2. While there may be varying opinions on the need, it appears that PowerPath is no longer required when using the new Windows Server operating systems. After trying various methods, I noticed a notation at the bottom of the screen indicating that for Windows Server 2012 R2, the built-in services were to be used.įurther research found that Microsoft has also built in multipath services into the 2012 R2 product.

EMC POWERPATH DOWNLOAD WINDOWS 2012 R2 SOFTWARE

However, I could not locate a download for the teaming software for Windows Server 2012 R2.

EMC POWERPATH DOWNLOAD WINDOWS 2012 R2 DRIVERS

Once the operating system was installed, I went to the Emulex website to download the appropriate drivers and network teaming software. When the new equipment was purchased, part of the refresh was a migration to Windows Server 2012 R2 using Emulex FCoE adapters for connectivity. The previous Windows 2008 systems were connected to the SAN via fiber channel HBA’s and among other thing, had PowerPath installed in order to provide sufficient failover and load balancing to a VNX. "Boot from SAN" step by step with Windows 2012 R2 and Cisco UCS using Brocade and EMC VNX.Recently, I was assigned the task of performing a hardware refresh in the datacenter. Now in vCenter service provider, setup connection to SMI-S again. Paste into the textbox to submit the CA to SMI-S. Now open the sms.pem in and editor and copy the information from -Begin Certificate- to -End Certificate. # openssl pkcs12 -in sms.pkcs -out sms.pem # keytool -importkeystore -srckeystore sms.keystore -destkeystore /tmp/sms.pkcs -srcstoretype JKS -deststoretype PKCS12 Do this perform the following commands on vCSA: So which certificate do we import? well that would be the sms.keystore cert, but we need the cert as PEM data. Here we want to select option 3 and import CA certificate from file… Under security select “SSL Certification Management.

EMC POWERPATH DOWNLOAD WINDOWS 2012 R2 PASSWORD

Username and password the same (admin / #1Password) I sticked with SMI-S since it provides more customization in administration console. Looking further at the sps.log file I figured the problem had to be with the vCenter server that is sending the certificate to the array. this can be verified by running the command “symcfg list” or logging in with testsmiprovider.exe and executing “dv” command. – Verify that there is an array connected to SMI-S. – For user authentication if you create a local user on VNX, then be sure to add local\username for authentication in service provider. – Verified the user created on VNX has VM administrator role. – I added the vCenter server certificate to trusted certificates on VNX – I restarted the array’s management server. – I regenerated the storage management certificates and restarted the vCenter server appliance

emc powerpath download windows 2012 r2

Some further troubleshooting was in order: To further test this I installed a windows 2012 server with SMI-S. # keytool -keystore sms.keystore -storepass testpassword -list -vĬheck the valid from and until in the output provided. This can be verified with the following commands on vCSA: The most common issue that seems to be related to the VASA configuration is a expired certificate for the storage monitoring server. In vCSA i reviewed the following error messages in sps.log under \var\logs\vmware\vpx\sps\ When trying to connect directly to VNX block I received the following error message: Select Manage tab in right pane -> Storage provider sub-tab. On vCenter server web client select your vCenter server in inventory list on left. Our VNX 5300 has FLARE 5.32 which should allow for straight connectivity to the VNX… VMware compatibility guide for EMC VASA provider specifies that VASA support is part of VNX Block OE 05.32 no additional software is required. VASA configuration should be straight forward but ran into some strange issues which took some extensive troubleshooting: Over weekend I wanted to review some of the features and functionalities that VASA and VSI provides inside vCenter server for a VNX array(5300).












Emc powerpath download windows 2012 r2